11
smartCUE Interfaces | User Manual | Setup the Unit
Setup the Unit
Wired Models
To get access to the factory default configured unit provide following steps
1. Set manually PC Local Area Connection (Ethernet network adapter) to
▪ IP address: 192.168.1.x where x = 1 to 253
▪ Subnet mask: 255.255.255.0
2. Connect the interface to PC. Use crossover cable for direct connection between PC and smartCUE if
your PC ethernet adapter doesn’t support auto-sense.
3. Use standard Internet browser and ll address line with http://192.168.1.254.
4. Provide setup using Admin Web. Use section Conguration / Network to set smartCUE connection to
target network. Settings depends on the network, however typically it is necessary to set
▪ IP address
Wireless Models
The unit uses Ad-Hoc wireless mode for initial setup. To get access to the factory default configured unit
provide following steps
1. Set manually your PC wireless adapter to
▪ IP address: 192.168.1.x where x = 1 to 253
▪ Subnet mask: 255.255.255.0
2. Disable all other PC network adapters which are congured as IP address 192.168.1.x (DHCP or static).
3. Switch on the smartCUE.
4. Connect your PC to wireless network Name: smartCUE
5. Use standard Internet browser and ll address line with http://192.168.1.254.
6. Provide setup using Admin Web. Use section Conguration / Network and Conguration / WiFi to
set smartCUE connection to target network. Settings depends on the network, however typically it is
necessary to set
▪ IP address
▪ Network name (SSID)
▪ Network type: Infrastructure (important step)
▪ Security type
▪ Security key